Features
Conductor Plain copper, finely stranded class 5 in accordance with DIN EN 60228 / IEC 60228
Insulation Ozone, water and weather resistant insulation compound, base EPR (Ethylene-Propylene Rubber)
Color code up to 5 cores: colored in accordance with DIN VDE 0293-308 more than 5 cores: DIN EN 50525-1 Annex D
Outer sheath EPR special compound type EM6 according to DIN EN 50363-2-1;
water resistant; Compound 3G357 Outer Sheath Colour Blue Electrical parameters
Rated voltage 450/750V Max. permissible
Operating voltage AC 0.476/0.825 kV Max. permissible operating voltage DC 0.619/1.238 kV AC Test Voltage 2.5 kV (15 Min.)
Chemical parameters Compatibility to drinking water ELL - (Elastomerleitlinie of Umwelt Bundesamt) Germany ACS - France Water resistance DIN EN 50525-2-21
Thermal parameters Max. permissible temperature at conductor 90 °C Max. short circuit temperature of the conductor 250 °C Max.
Permissible water temperature 60 °C (At higher water temperatures, a shortened cable service life is to be expected) Ambient temperature for fix Installation min. -50 °C Ambient temp. in fully flex. operation min. -50 °C
Applications
S07BBH2-F are intended for connection of electrical equipment in water and for medium mechanical stresses, e.g. submersible pumps, lowering of water level and booster plants. These cables are also suitable for use in drinking water, cooling water, surface water, rainwater. They further can be used in groundwater and seawater (salt water) up to 2000 m water depth. The outer sheath fulfills the requirements of health according to the "Elastomerleitlinien (ELL)" of the German "Umwelt Bundesamt" and the Attestation de Conformité Sanitaire (ACS) according to the French law. When corrosive water is involved, or water of some other special compositions must be investigated in each individual case. They may not be used in water containing more than 0,5 mg/l of chlorine. These cables can be used indoors, outdoors, in industrial and agricultural plant, but not in explosion-hazard areas. For protected, fixed installation within equipment, pipes or wells, as well as for rotor connections, these cables may be operated with an AC voltage to 1000 V or a DC voltage to 750 V with respect to earth. The permissible AC voltage for motor tests is 3 kV for a maximum duration of 3 minutes. In other respects the specifications of DIN EN 50565-2 apply. Global data Brand REPS Type designation S07BBH2-F Model Flat Standard DIN EN 50525-2-21 Notes on installation Maximum Submersing Depth 2000 Meter.
Conductor cross section |
Insulation thickness |
Approximate outer diameter |
Approximate weight |
Conductors at 20 ºC
Maximum resistance value |
mm² |
mm |
mm |
kg/km |
Ω/km |
0.5 |
0.6 |
2.2 |
9.0 |
39.0 |
0.75 |
0.6 |
2.4 |
11.8 |
26.0 |
1.0 |
0.6 |
2.6 |
14.5 |
19.5 |
1.5 |
0.7 |
3.0 |
21.4 |
13.3 |
2.5 |
0.8 |
3.7 |
33.4 |
7.98 |
4 |
0.8 |
4.3 |
48.9 |
4.95 |
6 |
0.8 |
4.85 |
69.0 |
3.3 |
10 |
1.0 |
6.6 |
115.9 |
1.91 |
16 |
1.0 |
7.6 |
174.2 |
1.21 |
25 |
1.2 |
10.0 |
270.5 |
0.78 |
35 |
1.2 |
11.0 |
367.6 |
0.554 |
50 |
1.4 |
12.94 |
522.7 |
0.386 |
70 |
1.4 |
14.54 |
711.4 |
0.272 |
95 |
1.6 |
16.86 |
962.9 |
0.206 |
120 |
1.6 |
18.26 |
1196.0 |
0.161 |
150 |
1.8 |
20.28 |
1495.0 |
0..129 |
185 |
2.0 |
22.6 |
1844.4 |
0.106 |
240 |
2.2 |
25.62 |
2383.4 |
0.0801 |
Wuxi Reps Power Technology Co., Ltd. is located in C Area, Guanlin Town, Yixing City, Jiangsu Province. Enterprise development environment is superior, convenient transportation conditions, is a focus on special cable research and development, design, manufacturing and sales of a full range of science and technology service enterprises.
Our company has all kinds of professional production and technical personnel to provide technical support, at the same time has advanced professional production line and a complete set of testing equipment, perfect testing system and strict process testing to ensure the stability of product quality.
The company's main flexible cable, drag chain cable, tensile wear-resistant coil cable, grab cable. Garbage cable, scraper cable, gantry cable, coil cable, high flexibility cable, encoder cable, robot cable, robot arm cable, palletizer cable, tower cable, crane cable, driving cable, crane cable, Spreader cable, container crane cable, cold resistant cable and all kinds of flat cable, polyurethane cable, etc. Cover fixed installation, mobile installation of data communication, power transmission, all kinds of wire and cable products used in extreme environment.
It involves railways, highways, data transmission, oil and gas plants and petrochemical industries, environmental power, mining and tunnels, ports and ships, drum winding and communication applications.
"Cable Customization" is a special service close to the user of the Reps brand. With our years of experience, we can analyze the challenges faced by customers and bring together our expertise and cutting-edge technology, research and design solutions for supporting cable, and carry out technical services.
Q1: How can Iplace order?
A: You can contact us by email about your order details, or place order online
Q2: Does your company provide OEM&ODM services?
A: Of course, we can produce cables by your samples or technical drawings
Q3: Doed your company test all your goods before delivery?
A. Yes. we have 100% test before delivery
Q4: Are you a cable and wire manufacturer?
A: Yes, our company is an integrated set of industry and trade company.
Q5: Can you offer free samples?
A: Sure, the price is negotiable. We will definitely give a discount based on your annual order.
Q6: How long is your delivery time?
A: Of course, according to your order quantity, we'd like to provide free sample.
Q7: What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. Trade terms of EXW, FOB, CFR, CIF,are available.