Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The pH measurement circuit has inherently a high internal resistance (up to 5x109 ohms in some cases) due to the fact that the potential voltage must pass through the membrane glass which adds resistance. Therefore the electrical connection to a pH meter or transmitter is prone to all kinds of electro-magnetic interference. For this reason specialized cable and connectors become important for the success of the pH measurement.
Part No. | Conductor | Insulation Thickness (mm) |
Diameter (mm) | Max. Resistance at 20ºC(Ω/km) |
Min. Insulation DCR at 70ºC(MΩ/km) |
||
mm2 | No./mm | Lower Limit | Upper Limit | ||||
H05V-U / 2491X (H05Z-U for LSZH) 300/500V | |||||||
H05V-U 0.5 | 0.5 | 1/0.80 | 0.6 | 1.9 | 2.3 | 36.0 | 0.014 |
H05V-U 0.75 | 0.75 | 1/0.97 | 0.6 | 2.1 | 2.5 | 24.5 | 0.013 |
H05V-U 1.0 | 1.0 | 1/1.13 | 0.6 | 2.2 | 2.7 | 18.1 | 0.011 |
H05V2-U 300/500V 90ºC | |||||||
H05V2-U 0.5 | 0.5 | 1/0.80 | 0.6 | 1.9 | 2.3 | 36.0 | 0.014 |
H05V2-U 0.75 | 0.75 | 1/0.97 | 0.6 | 2.1 | 2.5 | 24.5 | 0.013 |
H05V2-U 1.0 | 1.0 | 1/1.13 | 0.6 | 2.2 | 2.7 | 18.1 | 0.011 |
H05V-R (H05Z-R for LSZH) 300/500V | |||||||
H05V-R 0.5 | 0.5 | 7/0.30 | 0.6 | 2.0 | 2.4 | 36.0 | 0.014 |
H05V-R 0.75 | 0.75 | 7/0.37 | 0.6 | 2.2 | 2.6 | 24.5 | 0.012 |
H05V-R 1.0 | 1.0 | 7/0.43 | 0.6 | 2.3 | 2.8 | 18.1 | 0.011 |
H05V2-R 300/500V 90ºC | |||||||
H05V2-R 0.5 | 0.5 | 7/0.30 | 0.6 | 2.0 | 2.4 | 36.0 | 0.014 |
H05V2-R 0.75 | 0.75 | 7/0.37 | 0.6 | 2.2 | 2.6 | 24.5 | 0.012 |
H05V2-R 1.0 | 1.0 | 7/0.43 | 0.6 | 2.3 | 2.8 | 18.1 | 0.011 |
H05V-K / 2491X (H05Z-K for LSZH) 300/500V | |||||||
H05V-K 0.5 | 0.5 | 16/0.20 | 0.6 | 2.1 | 2.5 | 36.0 | 0.013 |
H05V-K 0.75 | 0.75 | 24/0.20 | 0.6 | 2.2 | 2.7 | 24.5 | 0.011 |
H05V-K 1.0 | 1.0 | 32/0.20 | 0.6 | 2.4 | 2.8 | 18.1 | 0.010 |
H05V2-K 300/500V 90ºC | |||||||
H05V2-K 0.5 | 0.5 | 16/0.20 | 0.6 | 2.1 | 2.5 | 36.0 | 0.013 |
H05V2-K 0.75 | 0.75 | 24/0.20 | 0.6 | 2.2 | 2.7 | 24.5 | 0.011 |
H05V2-K 1.0 | 1.0 | 32/0.20 | 0.6 | 2.4 | 2.8 | 18.1 | 0.010 |
H07V-U / 6491X (H07Z-U for LSZH) 450/750V | |||||||
H07V-U 1.5 | 1.5 | 1/1.38 | 0.7 | 2.6 | 3.2 | 12.1 | 0.011 |
H07V-U 2.5 | 2.5 | 1/1.78 | 0.8 | 3.2 | 3.9 | 7.41 | 0.01 |
H07V-U 4.0 | 4.0 | 1/2.25 | 0.8 | 3.6 | 4.4 | 4.61 | 0.0085 |
H07V-U 6.0 | 6.0 | 1/2.76 | 0.8 | 4.1 | 5.0 | 3.08 | 0.007 |
H07V-U 10.0 | 10.0 | 1/3.57 | 1.0 | 5.3 | 6.4 | 1.83 | 0.007 |
H07V2-U 450/750V 90ºC | |||||||
H07V2-U 1.5 | 1.5 | 1/1.38 | 0.7 | 2.6 | 3.2 | 12.1 | 0.011 |
H07V2-U 2.5 | 2.5 | 1/1.78 | 0.8 | 3.2 | 3.9 | 7.41 | 0.01 |
H07V2-U 4.0 | 4.0 | 1/2.25 | 0.8 | 3.6 | 4.4 | 4.61 | 0.0085 |
H07V2-U 6.0 | 6.0 | 1/2.76 | 0.8 | 4.1 | 5.0 | 3.08 | 0.007 |
H07V2-U 10.0 | 10.0 | 1/3.57 | 1.0 | 5.3 | 6.4 | 1.83 | 0.007 |
H07V-R / 6491X (H07Z-R for LSZH) 450/750V | |||||||
H07V-R 1.5 | 1.5 | 7/0.52 | 0.7 | 2.7 | 3.3 | 12.1 | 0.010 |
H07V-R 2.5 | 2.5 | 7/0.67 | 0.8 | 3.3 | 4.0 | 7.41 | 0.009 |
H07V-R 4.0 | 4.0 | 7/0.85 | 0.8 | 3.8 | 4.6 | 4.61 | 0.0077 |
H07V-R 6.0 | 6.0 | 7/1.04 | 0.8 | 4.3 | 5.2 | 3.08 | 0.0065 |
H07V-R 10.0 | 10.0 | 7/1.35 | 1.0 | 5.6 | 6.7 | 1.83 | 0.0065 |
H07V-R 16.0 | 16.0 | 7/1.70 | 1.0 | 6.4 | 7.8 | 1.15 | 0.005 |
H07V2-R 450/750V 90ºC | |||||||
H07V2-R 1.5 | 1.5 | 7/0.52 | 0.7 | 2.7 | 3.3 | 12.1 | 0.010 |
H07V2-R 2.5 | 2.5 | 7/0.67 | 0.8 | 3.3 | 4.0 | 7.41 | 0.009 |
H07V2-R 4.0 | 4.0 | 7/0.85 | 0.8 | 3.8 | 4.6 | 4.61 | 0.0077 |
H07V2-R 6.0 | 6.0 | 7/1.04 | 0.8 | 4.3 | 5.2 | 3.08 | 0.0065 |
H07V2-R 10.0 | 10.0 | 7/1.35 | 1.0 | 5.6 | 6.7 | 1.83 | 0.0065 |
H07V2-R 16.0 | 16.0 | 7/1.70 | 1.0 | 6.4 | 7.8 | 1.15 | 0.005 |
H07V-K / 6491X (H07Z-K for LSZH) 450/750V | |||||||
H07V-K 1.5 | 1.5 | 30/0.25 | 0.7 | 2.8 | 3.4 | 12.1 | 0.010 |
H07V-K 2.5 | 2.5 | 50/0.25 | 0.8 | 3.4 | 4.1 | 7.41 | 0.0095 |
H07V-K 4.0 | 4.0 | 56/0.30 | 0.8 | 3.9 | 4.8 | 4.61 | 0.0078 |
H07V-K 6.0 | 6.0 | 84/0.30 | 0.8 | 4.4 | 5.3 | 3.08 | 0.0068 |
H07V-K 10.0 | 10.0 | 80/0.40 | 1.0 | 5.7 | 6.8 | 1.83 | 0.0065 |
H07V-K 16.0 | 16.0 | 126/0.40 | 1.0 | 6.7 | 8.1 | 1.15 | 0.0053 |
H07V2-K 450/750V 90ºC | |||||||
H07V2-K 1.5 | 1.5 | 30/0.25 | 0.7 | 2.8 | 3.4 | 12.1 | 0.010 |
H07V2-K 2.5 | 2.5 | 50/0.25 | 0.8 | 3.4 | 4.1 | 7.41 | 0.0095 |
H07V2-K 4.0 | 4.0 | 56/0.30 | 0.8 | 3.9 | 4.8 | 4.61 | 0.0078 |
H07V2-K 6.0 | 6.0 | 84/0.30 | 0.8 | 4.4 | 5.3 | 3.08 | 0.0068 |
H07V2-K 10.0 | 10.0 | 80/0.40 | 1.0 | 5.7 | 6.8 | 1.83 | 0.0065 |
H07V2-K 16.0 | 16.0 | 126/0.40 | 1.0 | 6.7 | 8.1 | 1.15 | 0.0053 |
Q1: How can Iplace order?
A: You can contact us by email about your order details, or place order online
Q2: Does your company provide OEM&ODM services?
A: Of course, we can produce cables by your samples or technical drawings
Q3: Doed your company test all your goods before delivery?
A. Yes. we have 100% test before delivery
Q4: Are you a cable and wire manufacturer?
A: Yes, our company is an integrated set of industry and trade company.
Q5: Can you offer free samples?
A: Sure, the price is negotiable. We will definitely give a discount based on your annual order.
Q6: How long is your delivery time?
A: Of course, according to your order quantity, we'd like to provide free sample.
Q7: What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. Trade terms of EXW, FOB, CFR, CIF,are available.